Search results for "beam [charged particle]"
showing 10 items of 686 documents
Stopping cross-section measurements of 4He in TiN1.1O0.27
2000
Abstract The stopping cross-section for 4He projectiles in TiNx compounds has been measured using the backscattering method. A multi-compound marker layer deposited between the test film and the substrate was used to obtain the stopping cross-section at several energies with one energy of the incident beam. Two RBS spectra at definite tilt angles of the sample are taken for each beam energy. The assistance of computer codes to synthesize RBS spectra is very useful to obtain the pertinent information from the displacements of the peaks of the marker layers. Stopping cross-section values are obtained with an estimated uncertainty of about 6%.
Hot-cavity studies for the Resonance Ionization Laser Ion Source
2016
International audience; The Resonance Ionization Laser Ion Source (RILIS) has emerged as an important technique in many Radioactive Ion Beam (RIB) facilities for its reliability, and ability to ionize target elements efficiently and element selectively. GISELE is an off-line RILIS test bench to study the implementation of an on-line laser ion source at the GANIL separator facility. The aim of this project is to determine the best technical solution which combines high selectivity and ionization efficiency with small ion beam emittance and stable long term operation. The ion source geometry was tested in several configurations in order to find a solution with optimal ionization efficiency an…
ZnMgO-based UV photodiodes: a comparison of films grown by spray pyrolysis and MBE
2016
Detecting the UV part of the spectrum is fundamental for a wide range of applications where ZnMgO has the potential to play a central role. The shortest achievable wavelength is a function of the Mg content in the films, which in turn is dependent on the growth technique. Moreover, increasing Mg contents lead to an electrical compensation of the films, which directly affects the responsivity of the photodetectors. In addition, the metal-semiconductor interface and the presence of grain boundaries have a direct impact on the responsivity through different gain mechanisms. In this work, we review the development of ZnMgO UV Schottky photodiodes using molecular beam epitaxy and spray pyrolysis…
Oxy-nitrides characterization with a new ERD-TOF system
2017
Abstract A new time-of-flight (TOF) camera was installed on Elastic Recoil Detection (ERD) measurement setup on the Tandem Accelerator at Universite de Montreal. The camera consists of two timing detectors, developed and built by the Jyvaskyla group, that use a thin carbon foil and microchannel plates (MCP) to produce the start and stop signals. The position of the first detector is fixed at 18 cm from the target, while the position of the second detector can be varied between 50 and 90 cm from the first detector. This allows to increase time resolution by increasing the distance between the time-of-flight detectors or to increase solid angle by decreasing the distance. Moving the detector …
Direct observation of elemental segregation in InGaN nanowires by X-ray nanoprobe
2011
Using synchrotron radiation nanoprobe, this work reports on the elemental distribution in single Inx Ga1–xN nanowires (NWs) grown by molecular beam epitaxy directly on Si(111) substrates. Single NWs dispersed on Al covered sapphire were characterized by nano-X-ray fluorescence, Raman scattering and photoluminescence spectroscopy. Both Ga and In maps reveal an inhomogeneous axial distribution inside sin- gle NWs. The analysis of NWs from the same sample but with different dimensions suggests a decrease of In segregation with the reduction of NW diameter, while Ga distribution seems to remain unaltered. Photoluminescence and Raman scattering measurements carried out on ensembles of NWs exhibi…
Ion source research and development at University of Jyväskylä: Studies of different plasma processes and towards the higher beam intensities
2015
MonPS16; International audience; The long-term operation of high charge state electron cyclotron resonance ion sources fed withhigh microwave power has caused damage to the plasma chamber wall in several laboratories.Porosity, or a small hole, can be progressively created in the wall on a year time scale, which cancause a water leak from the cooling system into the plasma chamber vacuum. A burnout of theVENUS chamber is investigated. Information on the hole formation and on the necessary localhot electron power density is presented. Next, the hot electron flux to the wall is studied bymeans of simulations. First, the results of a simple model assuming that electrons are fullymagnetized and …
Inferior alveolar nerve trajectory, mental foramen location and incidence of mental nerve anterior loop
2017
Background: Injury of the inferior alveolar nerve (IAN) is a serious intraoperative complication that may occur during routine surgical procedures, such as dental implant placement or extraction of impacted teeth. Thus, the purpose of this study was to analyze the trajectory of the mandibular canal (MC), the location of the mental foramen (MF) and the presence and extension of an anterior loop of the mental nerve (AL). Study Design: In this cross-sectional study, a total of 348 CBCTs were analyzed. Distances from MC to the surface of the basal, medial and lateral cortical of the mandible were measured at the level of the second molar, first molar and second premolar. Location of the MF rela…
Evaluation of the position of the posterior superior alveolar artery in relation to the maxillary sinus using the Cone-Beam computed tomography scans
2017
Background The aim of the present study was to evaluate the diameter, relationship and position of the posterior superior alveolar artery and its relationship with the alveolar ridge, the medial wall of the maxillary sinus, the prevalence of pathologic conditions and the maxillary sinus septa on CBCT images. Material and Methods A total of 200 CBCT images (400 maxillary sinuses) of patients over 20 years of age were evaluated. The distances between the lower border of the artery and the alveolar crest and between the artery and the medial wall of the sinus and the diameter of the artery were measured. The position of the artery, the presence of pathologic conditions and septa were recorded …
Tooth abnormalities in individuals with unilateral alveolar clefts : a comparison between sides using cone-beam computed tomography
2017
Background: Tooth abnormalities are most often present in individuals with oral clefts than general population, and lead to a long-term impact on facial anatomy and self-esteem. The purpose of this study was to compare the proportion of dental anomalies between the cleft side and non-cleft side in individuals with non-syndromic unilateral alveolar clefts (AC). Material and Methods: Twenty cone beam computed tomography (CBCT) scans were converted into threedimensional (3D) virtual models. The dental anomalies considered were: tooth agenesis; supernumerary teeth; giroversion; and microdontia. Statistical analysis was performed using the McNemar?s test and Fisher?s exact test ( p < 0.05). Resu…
Surgically-oriented anatomical study of mandibular premolars: A CBCT study
2019
Background The knowledge of root canal anatomy and of the anatomical relationship should be considered mandatory when planning surgical endodontics. The aim of the study was to investigate the anatomical features of mandibular premolars, evaluating their relationship with mental nerve. Material and methods CBCT scans were evaluated recording the number of roots, root canal configuration and the relationship with mental nerve of 100 mandibular premolars. After simulating a resection of 3 mm of the root, the shape and the number of canals, and the distance to the buccal and lingual bone plate and to the mental foramen was evaluated. Results The one root - one canal configuration was the most …